22...: A general problem occurred with the local file system. Return value is: 0x... .
An error has occurred when accessing the local file system. The following list contains explanations of possible return codes.
22010001 Path not found
The function references a path that does not exist.
22010002 File not found
The function references a file that does not exist.
22010003 Entry already exists
The function references an element that already exists in the current path of the active partition on the Virtual Disk (i.e. it has been attempted to create a directory that already exists).
22010005 Access denied
An attempt was made to open a file, which is currently accessed by another user in UPDATE-mode.
22010006 Invalid Handle
A function call did not pass the handle, which has been assigned during the INIT-function.
22010007 File already open
An attempt has been made to open a file that is currently used by another user.
22010008 Directory not empty
An attempt has been made to delete a directory, but the directory still contains files.
First delete the files in the directory and then delete the directory.
22010012 No more entries available
The function has returned all entries to the calling application. The message indicates the end of data.
220A0000 Not enough memory
Not enough memory could be acquired for the function.
220A0001 Partition table is full
The reserved space for the partition table in the VSAM-Cluster of the Virtual Disk does not have sufficient free space to allocate a new partition.
Perform a BACKUP of the Virtual Disk, allocate a larger VSAM-Cluster and RESTORE the backup.
220A0002 No more storage for additional directory-entries available
An attempt is made to allocate a directory. The area used for directory entries does not have any free space left.
220A0003 No more data storage available
The partition on the Virtual Disk cannot contain more files. All formatted space is exhausted.
220B0000 Unexpected CICS error EIBRESP
An unexpected CICS error occurred. EIBRESP contains the hexadecimal return code. Consult the corresponding CICS-documentation for an explanation.
220E0000 Internal VDI error | Code=
Internal Virtual Disk error.
Please take note of the code and contact your local Rocket Software representative.
22100000 Invalid function code.
An invalid function code has been passed to the interface for the Virtual Disk.
22100001 Invalid function-sequence
An invalid sequence of function codes has been passed to the interface for the Virtual Disk (i.e. a CLOSE-function prior to an OPEN-function).
22100001 Invalid partition name
A partition name has been specified which does not exist.
22100003 Invalid partition size
An attempt has been made to format a partition using a wrong partition size.
Correct the size in the function call.
22100004 The function does not support generic names
Generic names have been passed as parameter with the function call, however the function does not support generic names.
22100005 Name contains invalid character
A file name has been specified in a function that contains an invalid character. The following characters must not be used in a name of a Virtual disk file: '*', '/', '?', '<', '>', ':'.
22110000 Base file not found
A Virtual Disk base file was specified in a function-call to the API of the Virtual Disk. The file does not exist. The base file is the name of the VSAM-file, which is defined in the Agents start-up parameter.
22110003 Authorization error during access
The user-id, who passed the function to the API of the Virtual Disk, is not authorized to access the Virtual Disk base file in this way.
22110005 Error during VSAM-READ 'LENGERR'
A VSAM length-error occurred when accessing the Virtual Disk base file.
Please contact your local Rocket Software representative.
22110006 No more space on Base file
There is no more space available on the Virtual Disk base file.
Perform a backup of the VSAM-file, redefine the Cluster with a larger space and restore the backup file.
22110008 Partitiontable was updated meanwhile
The partition table of the Virtual Disk base file has been modified. This error can only occur, when the base file can be used in UPDATE-mode by different systems (VSAM-SHAREOPTION=4). No data integrity is available when using this definition!
Make sure that you used the supplied definitions as documented in manual " Administration and Installation".
22140000 Error during READ of VSAM-record
A read error occurred when accessing the Virtual Disk base file.
Please contact your local Rocket Software representative
22180000 Beginning of file reached.
The access to a file of the Virtual Disk tried to position before the physical start of a file.
22190000 End of file reached
The access to a file of the Virtual Disk tried to read past the physical end of the file.
221A0001 Databuffer too small for this function
The defined data buffer is not large enough to keep the data returned by the interface.
221B0000 No Main Storage available
The Virtual Disk interface tries to execute a function and the main storage required for this function is not available
221C0000 Interface is not initialized
The Virtual Disk interface has not been initialized.
Make sure that the first function that was sent to the interface has been the INIT function.
221C0001 Interface for this file is not initialized
A function has been used for the Virtual Disk interface that relates to a base file, but this base file has not been referenced in the 'INIT'-function
221D0000 Partition not available
A function of the Virtual Disk interface relates to a partition that does not exist.
221D0001 Partition already available
A function of the Virtual Disk interface tries to create a partition that already exists and is formatted.
221D0002 Partition is inactive
A function of the Virtual Disk interface tries to work with an inactive partition
221D0003 Partition is already inactive
An attempt has been made to inactivate a partition that is already inactive.(Function 'INAP').
221D0004 Partition is already active
An attempt has been made to activate a partition that is already active(Function 'ACTP').
221D0005 Partition not deleted
An attempt has been made to perform an UNDELETE or RELEASE against a partition that is not deleted.
221D0006 Partition not released
An attempt has been made to format a partition with a name, that is already in use for a partition with a state of DELETE and the size of the new partition is larger than the size of the partition in the DELETE state. The partition with status DELETED must first be freed. ('FREP'-Function or RELEASE).
221D0007 Partitiontable currently in use
A function has been issued which requires an exclusive access to the partition table of the Virtual Disk. The access cannot be performed because the partition table is currently used exclusively by another function.
221D0008 Wrong version of VDISK-file
The Virtual Disk base file has not been formatted with the correct version or has not been correctly formatted.
Make sure to use the definitions as specified in manual "Host Administration and Installation" when creating and formatting the Virtual Disk base file.
221D0009 File not yet formatted
The Virtual Disk base file is not formatted. Make sure to use the definitions as specified in manual " Administration and Installation" when creating and formatting the Virtual Disk base file.
22E0000 TVSVDIB not found
A function of the batch interface of the Virtual Disk has been requested. However the interface could not be found. Make sure, that all relevant load libraries are part of the JOBLIB-STEPLIB or LIBDEF-definition.
22340000 Basefile has wrong format
The Virtual Disk base file has not been created in the right format.
Please check that the correct DEFINE CLUSTER-definitions (refer to manual "Host Installation and Administration") have been used and recreate the base file.
22600000 Error during OPEN of basefile
A VSAM error occurred during open of the Virtual Disk base file. A return code will be displayed. This is the code returned by VSAM. A description of the VSAM return codes can be found in the corresponding IBM documentation (z/OS: VSAM Programming, Chapter VSAM Return and Reason Codes, z/VSE: Messages and Codes, Chapter VSAM Return and Error Codes).
22610000 Error during CLOSE of basefile
A VSAM error occurred during close of the Virtual Disk base file. A return code will be displayed. This is the code returned by VSAM. A description of the VSAM return codes can be found in the corresponding IBM documentation (z/OS: VSAM Programming, Chapter VSAM Return and Reason Codes, z/VSE: Messages and Codes, Chapter VSAM Return and Error Codes).
22620000 VSAM MODCB error
A VSAM error occurred during the execution of a MODCB for the Virtual Disk base file. A return code will be displayed. This is the code returned by VSAM. A description of the VSAM return codes can be found in the corresponding IBM documentation (z/OS: VSAM Programming, Chapter VSAM Return and Reason Codes, z/VSE: Messages and Codes, Chapter VSAM Return and Error Codes).
22630000 VSAM PUT error
A VSAM error occurred during the execution of a PUT for the Virtual Disk base file. A return code will be displayed. This is the code returned by VSAM. A description of the VSAM return codes can be found in the corresponding IBM documentation (z/OS: VSAM Programming, Chapter VSAM Return and Reason Codes, z/VSE: Messages and Codes, Chapter VSAM Return and Error Codes).
22640000 VSAM GET error
A VSAM error occurred during the execution of a GET for the Virtual Disk base file. A return code will be displayed. This is the code returned by VSAM. A description of the VSAM return codes can be found in the corresponding IBM documentation (z/OS: VSAM Programming, Chapter VSAM Return and Reason Codes, z/VSE: Messages and Codes, Chapter VSAM Return and Error Codes).
22650000 VSAM LSR error
A VSAM LSR-error occurred (Local Shared Resources) for the Virtual Disk base file. A return code will be displayed. This is the code returned by VSAM. A description of the VSAM return codes can be found in the corresponding IBM documentation (z/OS: VSAM Programming, Chapter VSAM Return and Reason Codes, z/VSE: Messages and Codes, Chapter VSAM Return and Error Codes).